352 CU. IN. ENGINE Comp. Ratio 9.5-1 Comp. Pres. 120 PSI (MIN) MAX. VAR. 10 PSI Firing Order 1-8-4-3-6-5-7-2 |
IGNITION COIL Auto Lite CAD4004 Pri. Res. 1.65-1.79 OHMS Sec. Res. 8000-9200 OHMS PU4001 BALLAST RESISTOR .665-.735 OHMS CONDENSER CAPACITY .25-.285 MFD SPARK PLUGS Champion H10 Replacement N18 Gap - .033-.038 Torque 25/30 FT/LBS |
IDLE
SPEED Overdrive Trans.
550
Auto. Trans. 550 IGNITION
TIMING
Overdrive Trans. 5°
BTDC @ 600 rpm
Auto. Trans. 5° BTDC @ 600 rpm Dist. Vac. Line Disconnected IGNITION ADVANCE AT 2500 RPM Total Cent. Only IBJ-C-39-47½" 23½-27½" IBJ-E-35-43" 19-23" |
MODIFIED DISTRIBUTOR IBJ4001E Auto Lite IBJ4001C Rotation C.C. Spring Tension 17-20 Oz. Dwell 28-34° Gap .015-.017" Dwell Variation 3° MAX. |
DISTRIBUTOR
MECHANICAL ADVANCE |
VACUUM ADVANCE |
||
IBJ4001E
Dist. Dist.Deg. RPM Start 300 1° 375 8° 900 13° 2275 14° 2550 |
IBJ4001C
Dist. Dist.Deg. RPM Start 300 1° 350 10° 850 14° 1765 15° 2000 |
IBJ4001E
Dist.Deg. VAC. Start 8" 1° 85/8" 5° 11¼" 9° 14¾" 10° 16" |
IBJ4001C
Dist.Deg. VAC. Start 7" 1° 7½" 5° 95/8" 9° 121/8" 10° 13" |
|
SECONDARY
RESISTANCE - 3.0 MIN. |
GENERATORS |
REGULATORS |
||
STAND.
W/AIR COND. GJC7002F Auto Lite A Circuit Type 30A @ 15V Output 2250 Gen. RPM. 1000 Eng. RPM. Field Current 1.2-1.3A @ 10V @ 70° F |
STAND.
W/AIR COND. VRX6008A Auto Lite A Circuit Type Cutout Relay 13.0-13.75V Closing Volts 3-5A Open Amps .031-.034" Air Gap .015" Point Gap Volt. Reg. 14.2-14.8V Setting .048-.052" Air Gap |
CHARGING
CIRCUIT RESISTANCE (Volts @ 20 Amps)
INS. CIRC. .9V GRD. CIRC. .1V REG. GRD. .1V CHARGING VOLTAGE 13.9-14.6V |
FUEL
PUMP
Pres. 3½-5½ PSI @ 500 RPM Vol. 1 PT.-30 SEC @ 500 RPM Vac. 10" @ 500 RPM |
BATTERY 60 AH Neg. Grd. CRANKING VOLTAGE Min. 9.6V |